Kaloris 3W








































Kaloris 3W – for the most advanced heating systems
Three copper coils – even more possibilities
- Upper copper coil: For instantaneous domestic hot water preparation.
- Middle copper coil: For connecting an additional heat source or a separate heating circuit.
- Lower copper coil: For solar collectors, heat pumps or other low-temperature sources.
Kaloris 3W – maximum flexibility and performance thanks to three copper coils

Connection options:
- Different heating systems: Simultaneous operation of open and closed systems with full separation of technical fluids.
- Multiple heat sources: Boilers, heat pumps, solar collectors, fireplaces with a water jacket and photovoltaics.
- Multiple heat consumers: Radiators, underfloor heating, wall heating and domestic hot water.
- Circuit separation: Safe cooperation of installations with different parameters and fluids.
Safe Gravity System (SGS)
When connected to a solid-fuel boiler or fireplace with a water jacket, the Safe Gravity System (SGS) ensures control over correct device operation and protects the system against overheating, even in the event of:
- Power failure
- Circulation pump failure
Instantaneous domestic hot water heating in the Kaloris 3W buffer
Key benefits of Kaloris 3W:
- Unlimited amount of hot water – instantaneous heating guarantees constant access to DHW without waiting.
- Sanitary safety – flow technology prevents Legionella bacteria growth and ensures hygienic water.
- Real-time heating – hot water is delivered without delay and without reheating the tank.
- No water ageing – thanks to the flow system, water is always fresh and safe to use.
- Output of at least 24 l/min – comfort even in homes with high hot water demand.
- Hot water already at a tank temperature of 50°C – energy savings and lower bills.
- No need to replace a cathode or anode – low-maintenance operation.
Copper coil – safety and hygiene
Thanks to the copper coil used in Kaloris 3W, water remains hygienic and safe. Copper inhibits bacterial growth, making the system ideal for places with high sanitary requirements, such as:
- Hospitals
- Kindergartens
- Nurseries
- Schools
3-in-1 functionality of Kaloris 3W – a complete heating system
3-in-1 functionality – a complete boiler room in one device
- Buffer: Stores heat from various sources, such as heat pumps, solid-fuel boilers, fireplaces with a water jacket and solar installations. This allows Kaloris 3W to provide stable heat supply and uninterrupted system operation.
- Heat exchanger: Works as an instantaneous domestic hot water heater. Thanks to the copper coil, water heating is hygienic and fully safe, eliminating the risk of Legionella growth.
- Hydraulic separator: This is the central function of Kaloris 3W. The device acts as a natural hydraulic separator, separating and stabilising the flows of technical fluids. It enables connection and integration of multiple heat sources and heat consumers, ensuring performance and operational safety of the entire heating system.
Hydraulic separator in practice
Kaloris 3W as a separator for hybrid boiler rooms enables:
- Combining open and closed systems – simultaneous cooperation of systems with different operating parameters.
- Separation of technical fluids – prevents glycol from mixing with domestic water or other heating fluids.
- Stabilisation of heating flows – ensures even system operation and protects devices from overload.
- Integration of multiple heat sources – such as gas boilers, heat pumps, fireplaces, solar installations and heat recovery devices.
- Optimisation of circulation pump operation – reduces operating costs through precise fluid flow management.

| Technical parameters | Values |
|---|---|
| Tank material: | S235JR, 3 mm thick |
| Insulation: | rock wool |
| Protective jacket: | eco leather |
| Tank operating pressure: | 3 bar |
| DHW operating pressure: | 6 bar |
| Permissible operating temperature: | 95ºC |
| Coil material: | copper |
| Heat exchange area of the DHW coil: | from F=2.8 m² to 3.4 m² |
| DHW output: | from 1400 l/h to 2400 l/h |
| Heat exchange area of the middle coil: | from F=1.7 m² |
| Heat exchange area of the lower coil: | from F=1.7 m² |
| Tank operation: | open and closed systems |
| Warranty: | 10 years |
Available models
| Device model | Heating output | DHW flow | Volume | Diameter | Height | Weight | Technical sheet |
|---|---|---|---|---|---|---|---|
| 700 / 3W / 40 | 20 - 30 kW | 40 L/min | 610 L | 800 mm | 2000 mm | 170 kg | <a href="wp-content/uploads/2023/09/Zbiornik-Noel-7003W_aktualne_2023.pdf">.pdf </a> <span aria-hidden="true" class="et-pb-icon">"</span> |
| 900 / 3W / 40 | 30 - 50 kW | 40 L/min | 830 L | 900 mm | 2100 mm | 225 kg | <a href="/wp-content/uploads/2023/09/Zbiornik-Noel-9003W_aktualne_2023.pdf">.pdf </a> <span aria-hidden="true" class="et-pb-icon">"</span> |
| 900 / 3W / 40 SLIM | 30 - 50 kW | 40 L/min | 830 L | 820 mm | 2500 mm | 225 kg | <a href="/wp-content/uploads/2018/07/900_3W_40.pdf">.pdf </a> <span aria-hidden="true" class="et-pb-icon">"</span> |
| 1200 / 3W / 40 | + 50 kW | 40 L/min | 1120 L | 1000 mm | 2200 mm | 230 kg | <a href="/wp-content/uploads/2023/09/Zbiornik-Noel-12003W_aktualne_2023.pdf">.pdf </a> <span aria-hidden="true" class="et-pb-icon">"</span> |
| 1200 / 3W / 40 SLIM | + 50 kW | 40 L/min | 1120 L | 920 mm | 2600 mm | 245 kg | <a href="/wp-content/uploads/2023/09/Zbiornik-Noel-12003W_aktualne_2023.pdf">.pdf </a> <span aria-hidden="true" class="et-pb-icon">"</span> |
| 1500 / 3W / 40 | + 50 kW | 40 L/min | 1320 L | 1000 mm | 2700 mm | 260 kg | <a href="/wp-content/uploads/2018/07/Zbiornik_Noel_1200_3W.pdf">.pdf </a> <span aria-hidden="true" class="et-pb-icon">"</span> |
* We can adapt each of our models to the individual needs of the user. We will adjust the tank size, heater placement, additional connectors or a different connector layout. For areas above 300 m², the model is selected individually.
Would you like to learn more about the device?
Ensure efficient heating with NOEL
Do not let the cold disturb your comfort. Contact us to learn more about our reliable and efficient heating systems.